Home
>
Products
>
Gas Detection & Instrumentation
>
Calibration & Bump Test Stations
>
Part # 8328605

Draeger 8328605 X-dock®X-dock®

D-47836-2012_1000.png
featured
CAD$1,175
View Item Specs
View Inventory

Quantity

-+
Buy Now
Add to QuickList

Overview

Scalable calibration and configuration station to perform bump tests, create reports & calibration certificates for the portable detectors Draeger® X-am® 125 and Draeger® Pac® series and to administer a robust gas detector fleet.

Features

The X-Dock®'s engineered advantage all starts with intuitive touchscreen operation at the master controller station where up to three test routines can be configured. Testing is as simple as inserting your Draeger® gas detection instrument and closing the lid. The X-Dock® immediately detects all sensor combinations and automatically tests and adjusts when all of the required test gases are connected. All generated data is documented in the database.

Comprehensive Documentation

All of the relevant data from the test is collected for detailed evaluations providing you with the tools for unparalleled analytics. The report wizard can be used to create customized reports and calibration certificates can be printed right at the stations via PostScript-compatible USB printers. Also documented are items such as instrument operational status and name of tester.

Convenience & Control

The X-Dock® Manager software produces a detailed evaluation of the data in the calibration system and gas detection instruments, and presents the information in various graphics and statistical models €“ providing you with a comprehensive overview of all results. Multiple X-Dock® systems can be connected in a network giving all users access to data in a central database.

Configurations For Every Need

The Draeger® X-Dock® comes in multiple configurations to allow for flexibility depending on the type of detection instrumentation being used. The X-Dock® 5300 includes a master controller with a module for a single gas detection instrument in the X-am® 1/2/5000 or Pac1) family of products. The X-Dock® 6300 and 6600 versions can be configured freely. They consist of a master controller and can be expanded with up to 10 modules for X-am® 1/2/5000 and/or Pac single gas detection instruments.

Reduced Test Gas Use Means Reduced Costs

With a reduced gas flow (300 mL/min instead of 500 mL/min = 40 % decrease) per module, you save money on test gases. Short testing times also reduce the overall maintenance requirements. Draeger€’s patent pending innovative valve concept only needs one pump, which means less wear on parts for you. The valves automatically switch the test gases and the fresh air source as well.

Time is Money. You Save Both With The X-Dock®

Up to 10 modules can be connected to the X-Dock®, allowing you to test gas detection instruments simultaneously or independently of each other. The automatic bump test also saves time, because the test only takes 8 to 15 seconds. All Draeger® test gas cylinders are already stored in the database €“ just enter the part number to automatically fill the fields required for the gas configuration, eliminating the need for manual data entry

Further Benefits

  • Touchscreen operation at the master controller station

  • Up to three configurable test routines

  • Automatic permeability tests

  • Automatic tests of all alarm elements (acoustic, visual and vibration alarms)

  • Optional charging function for X-am® 1/2/5

  • Easy to replace seal cartridge 12V operation (e.g., in vehicles) available

  • Can be subsequently expanded with up to max. 10 modules (X-Dock® 6300/6600)

  • Sensor performance testing

The X-Dock® Manager Offers...

  • An overview page

  • Gas exposure in specific areas,

  • Number of executed tests

  • Device availability

  • Overview of created/sent reports

  • Templates for regular reports

  • An issue and return function

  • Monitoring of stations in the network

  • Overview of devices

Technical Information

X-Dock® 5300

Order the X-Dock® 5300 System if you only wish to have a single instrument module. This means you can only calibrate, bump test, or update a single monitor at a time. This is a good option if you only have one or a few monitors and if you use either Pac® or X-am® Series of monitors and not both in your fleet. The X-Dock® 5300 also limits you from charging your X-am® Series monitors if you have rechargeable batteries installed.

X-Dock® 6300 or X-Dock® 6600

If you wish to test, calibrate and manage multiple (up to ten) gas detectors at the same time, order the X-Dock® 6300 or X-Dock® 6600 systems. The main difference between these two systems is that the X-Dock® 6600 system has up to 6 unique calibration gases at the same time to allow for various sensors in various monitors to run simultaneously. The X-Dock® 6300 system can accommodate up to 3 calibrations gases only.

Manufacturer

Draeger
Browse all Draeger

Brand

Browse all X-Dock®
Related
Similar
New
Recommended
You Recently Viewed
Need Help?
Your Source For Safety Canada's most comprehensive safety equipment database
Company Products Services About Us Promotions Manufacturers & Brands Documents & FAQs
Customer Support View Your Order Return Policy Shipping Policy Credit and Payment Services Contact Us
Sitemap | Terms of Sale | Terms of Use | Privacy Policy
Copyright © 1998-2025 International Safety Systems Inc. 🤝 Custom Software developed by BiteSite Inc.